Construction:

| Conductor | 12AWG stranded tinned copper to IEC60228 Class 2 |
| Insulation | XLPE compound. Nominal outer diameter 3.75mm |
| Insulation Color | Blue, Brown and Green/Yellow |
| Conductor | 22AWG stranded tinned copper to IEC60228 Class 2 |
| Insulation | PE material. Thickness 0.4mm |
| Insulation Color | Black and White |
| Shield | Aluminium polyester tape with 24 AWG stranded tinned copper drain wire |
| Sheath | LSZH sheath. Nominal outer diameter is 4.8mm |
| Sheath Color | Black and Grey |
| Optical Fiber | Multi-mode cabled fibers meet or exceed the requirements of ITUT G.651 specification |
| Loose Tube | PBT tubes contains 4 fibers. The tubes are filled with a thixotropic gel to prevent the ingress of water |
| Aramid Yarn |
Aramid Yarn is laid over the tube core to serve as peripheral strength member |
| Sheath | LSZH outer Sheathis extruded over the glass yarn. Nominal outer diameter is about 5.0mm |
| Sheath Color | Black |
Element Assembly
| Wrapping Tape | Polyester tape or woven tape |
| Inner Jacket | Black LSZH, thickness 1.0mm |
| Armor | Galvanized steel wire braid, coverage 95% |
| Sheath | FR-LSZH, thickness 1.6mm, nominal outer diameter 19.5±1.5mm |
| Sheath Color | Black |